But just not through SCCM. If it Helps, Please rate.... #14 dcslick Total Posts : 32 Scores: 0 Reward points : 4590 Joined: 6/11/2009 Status: offline RE: problem with advertisement Tuesday, September 15, 2009 2:40 Note that if the $(ProjectDir) or similar macro terms have spaces in the resulting paths when expanded, then they will need to be wrapped in double quotes. But from SMS system status it showed no program success. http://gbnetvideo.net/exit-code/exit-code-512-in-unix.html

When compiling in visual studio 2010, I get the following: The command "xcopy C:\Users\Me\Path\Foo.bar\Library\dsoframer.ocx C:\Users\Me\Path\Foo.bar\bin\Debug\ /Y /E /D xcopy C:\Users\Me\Path\Foo.bar\ApplicationFiles C:\Users\Me\Path\Foo.bar\bin\Debug\ /Y /E /D xcopy C:\Users\Me\Path\url\ C:\Users\Me\Path\Foo.bar\bin\Debug\ /Y /E /D rmdir Then start engine from user interface and test task again. share|improve this answer answered Mar 28 '14 at 5:18 A.R 164115 add a comment| up vote 2 down vote I had the same error with xcopy in connection with the Test execmgr 9/9/2009 9:57:45 AM 1368 (0x0558) CUIEventGenerator::ClearNewProgramAvailable entered execmgr 9/9/2009 9:57:45 AM 1368 (0x0558) CUIEventGenerator::ClearNewProgramAvailable succeeded execmgr 9/9/2009 9:57:45 AM 1368 (0x0558) Cached CCM (user, session) is: (S-1-5-21-1670625886-1014624808-1798593698-1278,1). https://jvrtech.net/2015/12/10/script-for-package-failed-with-exit-code-4-in-sccm-2012-r2/

Xcopy Exit Code 2

You might need to enable user interaction in the program If it Helps, Please rate.... #6 rbennett806 Total Posts : 1017 Scores: 43 Reward points : 18620 Joined: 6/14/2006 Status: Martin Smith Website: www.IndustrialArcServices.com.au SCCM Engineer - going balder by the day #3 hcortez463 Total Posts : 1144 Scores: 95 Reward points : 26830 Joined: 4/8/2005 Status: offline RE: problem Here is the error I receive in the Event Viewer. All Forums >> [Management] >> System Center Suite >> [Configuration Manager] >> ConfigMgr 2007 Forum MenuPhoto GalleriesLog inRegistration / Sign up RSS FeedThread Options View Printable PageThread Reading Mode problem with

more stack exchange communities company blog Stack Exchange Inbox Reputation and Badges sign up log in tour help Tour Start here for a quick overview of the site Help Center Detailed Thanks –ValidfroM Nov 21 '13 at 14:11 add a comment| up vote 5 down vote In case the post build event contains copy/xcopy command for copying build output to some directory(which Copy to specific locations require admin rights. –Nikhil Agrawal Jul 28 at 9:59 add a comment| 9 Answers 9 active oldest votes up vote 105 down vote accepted Xcopy exit code Xcopy Sharing Violation LOTS easier.

With these two measures, I haven't had a problem related to exit codes. Xcopy Exit Code 4 Remove space for the directory name(s) and try. Although now I have 2 copies of the files and need to delete one. http://www.hiteksoftware.com/knowledge/email/025.htm execmgr 9/9/2009 9:59:56 AM 4724 (0x1274) CExecutionRequestManager::OnTimer - Processing UI Notify Timer execmgr 9/9/2009 9:59:56 AM 4724 (0x1274) Entering CTimerTask::CancelTimer.

Marked as answer by Eric MattoonMicrosoft employee, Moderator Monday, March 18, 2013 4:34 PM Tuesday, March 12, 2013 7:30 PM Reply | Quote All replies 0 Sign in to vote Try Exit Code 4 Linux execmgr 9/9/2009 9:57:45 AM 1368 (0x0558) Cached CCM (user, session) is: (S-1-5-21-1670625886-1014624808-1798593698-1278,1). After running the script, look in the Windows Event Viewer logs (the Application log) for events with a source of "WSH". 3. Hot Network Questions Is there any indication in the books that Lupin was in love with Tonks?

Xcopy Exit Code 4

There is nothing wrong with the script because I can run the script and it does install the shortcut. Coup: Can you assassinate yourself? Xcopy Exit Code 2 We have an external bin folder that was causing the issue described. Xcopy Error Codes share|improve this answer answered Oct 5 '10 at 7:30 Preet Sangha 47.9k1494156 3 I added the /C option to above xcopy command and the build succeded.

http://www.hiteksoftware.com/knowledge/articles/038.htm http://www.hiteksoftware.com/knowledge/articles/040.htm 4) Are you using the NT service module? check my blog But when putting it in SCCM I have the same problem, it fails when it tries to run. One partial solution I found is to use the /C option for xcopy (which continues on error). In this way you dont have to create a new package every time you get new source. Xcopy Exit Codes

Oh well, none of the other threads with this problem got solved, so hopefully this will be useful to someone else. Set the advertisement to run always and suppress user notification. Once I removed the read-only attribute, the error dissappeared when trying to build the solution. –eniacAvenger Dec 12 '14 at 17:24 Can somebody show the full xcopy.. –Ziggler May this content Re-saving the file specified in the /exclude option causes it to work again.

Here's a sample VBScript code to copy a shortcut from the source directory to the machine (just put the shortcut in the same folder as the VBScript file): Option Explicit Dim Xcopy Syntax share|improve this answer answered Sep 16 at 18:54 BinaryTony 112 add a comment| protected by Marco A. Related About oleggap IT Pro View all posts by oleggap → This entry was posted in SCCM.

Would you like to answer one of these unanswered questions instead?

DC #1 msmith515 Total Posts : 109 Scores: 5 Reward points : 23270 Joined: 11/30/2008Location: Brisbane, QLD, Australia Status: How can I monitor the progress of a slow upgrade? Browse other questions tagged c# visual-studio-2010 visual-studio-2012 xcopy or ask your own question. Xcopy Overwrite Thursday, March 07, 2013 2:00 PM Reply | Quote Answers 1 Sign in to vote Why not put the files in the package?

How can I place the article date before the title? up vote 8 down vote favorite 3 I'm using an SCCM 2012 application deployment to install software. Right-click on the folder-->Properties-->Security solved the problem for me on a stand alone XP SP3 system Thank YOU –user2597301 Oct 9 '13 at 19:54 add a comment| up vote 2 down have a peek at these guys Pseudo-currying in one line Why does rotation occur?

strAllUsersProgramsPath = objWshShell.RegRead("HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\Explorer\Shell Folders\Common Programs") strAllUsersDesktopPath = objWshShell.RegRead("HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\Explorer\Shell Folders\Common Desktop") strCommonAppDataPath = objWshShell.RegRead("HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows\CurrentVersion\Explorer\Shell Folders\Common AppData") ' Attempts to configure Windows 2000/XP paths. Hope it helps someone! If you choose to participate, the online survey will be presented to you when you leave the Technet Web site.Would you like to participate? share|improve this answer answered Nov 21 '13 at 12:47 rhughes 4,74243267 add a comment| up vote 1 down vote I faced same issue.

The .bat file copies and deletes some files from both the local machine and some mapped drives. Any ideas? Register now! There is not enough memory or disk space, or you entered an invalid drive name or invalid syntax on the command line." It looks like Visual Studio is supplying invalid arguments

For this specific shortcut I have built the collection group, the package, vb script for the install, and the advertisement. When the new source is available, update the DPs with new source using the same package. Back to top Back to Configuration Manager 2007 0 user(s) are reading this topic 0 members, 0 guests, 0 anonymous users Reply to quoted postsClear www.windows-noob.com → Windows Server → Event ID 10016 in Source DCOM The application-specific permission settings do not grant Local Launch permission for the COM Server application with CLSID {24FF4FDC-1D9F-4195-8C79-0DA39248FF48} to the user NT AUTHORITY\SYSTEM SID (S-1-5-18)

How do you output return codes from powershell so that SCCM can interpret them? Oct 5 '10 at 8:11 2 I had this issue because one of the files was read-only. This is because of the post-build event not being able to go through. What is shiny and makes people sad when it falls?

Does being engaged (to be married) carry any legal significance? What does the script look like?