more stack exchange communities company blog Stack Exchange Inbox Reputation and Badges sign up log in tour help Tour Start here for a quick overview of the site Help Center Detailed Is there any indication in the books that Lupin was in love with Tonks? All rights reserved. Any parameters in addition to that will be stored on the stack. http://gbnetvideo.net/failed-to/org-apache-http-nohttpresponseexception-failed-to-respond.html

If WAS is not running, or if errors occur during the startup or shutdown of an application pool, Web sites and Web applications may not be available. IIS Windows Process Activation Service (WAS) IIS Application Pool IIS Application Pool Availability IIS Application Pool Availability Event ID 5010 Event ID 5010 Event ID 5010 Event ID 1026 Event ID I have seen this error many times in the past and I just simply ignore it (as it does not cause any damage to my site and apps). A word for something that used to be unique but is now so commonplace it is no longer noticed Since New York doesn't have a residential parking permit system, can a https://blogs.msdn.microsoft.com/pfedev/2012/09/30/troubleshooting-event-id-5010-iis-application-pool-availability/

A Process Serving Application Pool Failed To Respond To A Ping 5010

Thanks. As it turns out, that is exactly what happens in this case. For example, though the steps at the bottom of the page work for IIS 7, 7.5, and 8, I haven’t tested them with IIS 6 or below. But I am not getting this message instead of the previous one.

Event Type: Warning Event Source: W3SVC Event Category: None Event ID: 1010 Date: 5/18/2006 Time: 2:17:19 PM User: N/A Computer: ******* Description: A process serving application pool 'DefaultAppPool' failed to respond HTH, [email protected] http://webperf.com.au Reply gww 33 Posts Re: application pool stops responding May 22, 2006 08:45 AM|gww|LINK I found the application that is having problems, but unsure why. Reply Skip to main content Follow UsPopular Tags.NET Debugging WinDBG Zach .NET General Tools Java Script VS JavaScript IE Visual Studio PrakashPatel Visual Studio 2015 VS2015 Prakash Patel Web Browser Control A Process Serving Application Pool Msexchangeecpapppool Failed To Respond To A Ping If our breakpoint is correct, the debugger, still attached to the WAS process, should break in.

However, if this type of error does not cause anything to your site, you can simply ignore it. share|improve this answer edited Apr 27 '15 at 22:17 SliverNinja 1186 answered Feb 8 '10 at 19:46 Andy Shellam 1,5101915 add a comment| Your Answer draft saved draft discarded Sign A connection attempt failed because the connected party did not properly respond after a period of time, or established connection failed because connected host has failed to respond... https://technet.microsoft.com/en-us/library/cc734991(v=ws.10).aspx Treat my content as plain text, not as HTML Preview 0 … Existing Members Sign in to your account ...or Join us Download, Vote, Comment, Publish.

Worker process startup time-out. How To Use The Debug Diagnostics Tool To Troubleshoot A Process That Has Stopped Responding In Iis Worker process orphan action failure. If you’re currently experiencing this issue and just want to know how to get the memory dump of the Worker Process, feel free to skip down to the bottom. See ASP.NET Ajax CDN Terms of Use – http://www.asp.net/ajaxlibrary/CDN.ashx. ]]> TechNet Products Products Windows Windows Server System Center Browser

Event Id 1010 W3svc

For some reason the website just stoped responding. dig this Looking into the logs I found this. A Process Serving Application Pool Failed To Respond To A Ping 5010 For some reason, either threads are being blocked indefinitely or the CPU on your machine is so saturated that the worker process never gets the chance to respond to its health A Process Serving Application Pool 'msexchangeautodiscoverapppool' Failed To Respond To A Ping See the system event log for more information A process serving an application pool failed to respond to a ping.

Remember, stacks call stacks start at a higher address and grow down as they move up the stack. Check This Out It's called httperr.log and is usually in the log file directory C:\windows\system32\LogFiles, under the main W3CSVC1 service. http://subbarao515.wordpress.com Reply abivenkat Member 267 Points 207 Posts Re: A process serving application pool xxx failed to respond to a ping. Arguments of \newcommand as variable names? A Process Serving Application Pool 'asp.net V4.0' Failed To Respond To A Ping.

You can attach Debug Diagnostics tool to the process and take a dump to check what is causing the issue. How do I typeset a matrix in an inline equation? Too check out all the requests in flight. Source We’re searching for a word value because that’s plenty of space for the PID to be stored in and searching for our known PID, 8012.

0:002> s -[1]w @rsp-100 @rbp

Yes No Do you like the page design? A Process Serving Application Pool 'msexchangesyncapppool' Failed To Respond To A Ping. We’ll start by attaching the debugger to the WAS process and reloading symbols. To verify that an application pool has started: 1.Click Start , click Control Panel , and then click Administrative Tools . 2.Right-click Internet Information Services (IIS) Manager and select Run as

Is there a limit to the number of nested 'for' loops?

My question is: what would cause a "ping timeout" to all of the app pools around the same time, and then why would they start up too slowly? Clone yourself! As far as i know, there is IIS feature "Process Orphaning" (Application Pools -> Your Pool -> Advanced Settings). Communication Failure With Was. Solution 1 Accept Solution Reject Solution First of all you should not be using same AppPool for all your web applications/websites.

The process id was '%2'. Very helpful. unique stamp per SSH login Why doesn't Darth Vader's force-choke work and where is his lightsaber? http://gbnetvideo.net/failed-to/failed-to-setautocommit-to-true-for-pool.html If however, we’re working on a machine that has a lot of worker processes, it may be more beneficial to find the actual worker process being referred to and just dump

So, we don’t have the PID on the call stack. Yes No Additional feedback? 1500 characters remaining Submit Skip this Thank you! General FAQ Ask a Question Bugs and Suggestions Article Help Forum Site Map Advertise with us About our Advertising Employment Opportunities About Us Ask a Question All Questions All Unanswered FAQ Event ID 5010 — IIS Application Pool Availability Updated: January 20, 2010Applies To: Windows Server 2008 Web sites and Web applications depend on the availability of Internet Information Services (IIS) application

We can set a breakpoint on that line item, tell the process to continue, then intentionally cause a failed ping request to see if the breakpoint trips. 0:000> bp iisw3adm!WORKER_PROCESS::PingResponseTimerExpiredWorkItem All rights reserved. How to describe a person who always prefers things from other countries but not from their home countries? We need to let the debugger continue, create and pause another worker process, let the debugger break in at our earlier breakpoint, then validate that RCX+72 points to the new PID.

See event ID 701 in the application event log for more information TOC Collapse the table of content Expand the table of content This documentation is archived and is not being Details   Product Name Exchange Product Version 14.0 (Exchange 2010) Event ID 5010 Event Source Microsoft-Windows-WAS Category KHI Alert Type Warning Rule Path Microsoft Exchange Server/Exchange 2010/Common Components/Remote PowerShell Rule Name Event Information According to Microsoft : Cause : This event is logged when a process serving application pool failed to respond to a ping. Review the description of the alert that includes the variables specific to your environment.

Application Lifecycle> Running a Business Sales / Marketing Collaboration / Beta Testing Work Issues Design and Architecture ASP.NET JavaScript C / C++ / MFC> ATL / WTL / STL Managed C++/CLI It seems likely that the module responsible will either be one of the IIS processes or a process with w3 in the name. RCX was clearly not a parameter, but it’s a common enough register that it is still good to check. The process id was 5548.